New installation after institution already activated on T3C System

It is possible to have installed only one node of T3C Service within one institution for data consistency and communication with central T3C Server. If you need to install multiple nodes, install T3C Service on server computer and to other computers install only T3C Console.

  • Registration files from backup, consisting of: pk.pem and main.conf
  • Passphrase for private key, if it is secured
  • Administrator privileges for Microsoft Windows operating system

This installation procedure applies to T3C version 13 and higher.

  • Run the installer
  • Select a language
  • Choose setup type
    • Install only Console
      • Choose if you already have a server (T3C master node) installed within your organization and want to install another client
    • Install all components
      • Choose if this is the only installation for the organization or the server installation for the organization
      • Do not choose if this is another client installation within the organization
  • Confirm the destination folder for the installation
  • Install
  • If you have installed all the components:
    • At the end of installation, activation of institution registration is started, cancel it
    • Copy/extract registration to %PROGRAMDATA%\TatraMed Software\T3C\Service\conf folder
    • Verify that in Service\conf folder there are files pk.pem and main.conf
    • Rerun the installation again, to enable update of configuration files to latest version
  • If you have installed only T3C Console, setup connection to T3C Service installed on another computer